{"product_id":"techometer-48-48mm-socket-type-h7cx-r11d1-n-omron","title":"TECHOMETER 48 × 48MM SOCKET TYPE H7CX-R11D1-N OMRON","description":"\u003cdiv class=\"component-blockA01\"\u003e\n\u003cdiv class=\"text\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"table-blockA01\"\u003e\n\u003ctable border=\"0\" cellspacing=\"0\" class=\"tableA01\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"first-child\"\u003e\n\u003cth colspan=\"2\" rowspan=\"1\" class=\"heading right middle\"\u003e\u003cstrong\u003eClassification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth colspan=\"5\" rowspan=\"1\" class=\"heading center middle\"\u003e\u003cstrong\u003eTachometer\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" rowspan=\"1\" class=\"heading right middle\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth colspan=\"4\" rowspan=\"1\" class=\"heading center middle\"\u003e\u003cstrong\u003eH7CX-R11[]-N\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth class=\"heading center middle\"\u003e\u003cstrong\u003eH7CX-R11W[]-N\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" rowspan=\"1\" class=\"heading left middle\"\u003e\u003cstrong\u003eInput mode\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd colspan=\"4\" rowspan=\"1\" class=\"left middle\"\u003e1 input only\u003c\/td\u003e\n\u003ctd class=\"left middle\"\u003e2 inputs only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"3\" class=\"heading left middle\"\u003e\u003cstrong\u003eRatings\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth class=\"heading left middle\"\u003e\u003cstrong\u003ePower supply\u003cbr\u003evoltage *1\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd colspan=\"5\" rowspan=\"1\" class=\"left middle\"\u003e100 to 240 VAC, 50\/60 Hz\u003cbr\u003e12 to 24 VDC or 24 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"heading left middle\"\u003e\u003cstrong\u003eOperating voltage\u003cbr\u003efluctuation range\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd colspan=\"5\" rowspan=\"1\" class=\"left middle\"\u003e85% to 110% of rated supply voltage (90% to 110% at 12 to 24 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"heading left middle\"\u003e\u003cstrong\u003ePower\u003cbr\u003econsumption\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd colspan=\"5\" rowspan=\"1\" class=\"left middle\"\u003eApprox. 9.4 VA at 100 to 240 VAC, Approx. 7.2 VA\/4.7 W at 24 VAC\/12 to 24 VDC, Approx. 3.7 W at\u003cbr\u003e12 to 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" rowspan=\"1\" class=\"heading left middle\"\u003e\u003cstrong\u003eMounting method\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd colspan=\"5\" rowspan=\"1\" class=\"left middle\"\u003eFlush mounting or surface mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" rowspan=\"1\" class=\"heading left middle\"\u003e\u003cstrong\u003eExternal connections\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd colspan=\"5\" rowspan=\"1\" class=\"left middle\"\u003e11-pin socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" rowspan=\"1\" class=\"heading left middle\"\u003e\u003cstrong\u003eDegree of protection\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd colspan=\"5\" rowspan=\"1\" class=\"left middle\"\u003eIEC IP66, UL508 Type 4 (indoors) for panel surface only and when Y92S-29 Waterproof Packing is used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" rowspan=\"1\" class=\"heading left middle\"\u003e\u003cstrong\u003eInput signals\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd colspan=\"4\" rowspan=\"1\" class=\"left middle\"\u003eCount and hold\u003c\/td\u003e\n\u003ctd class=\"left middle\"\u003eCount 1 and count 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" rowspan=\"1\" class=\"heading left middle\"\u003e\u003cstrong\u003ePulse measurement method\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\" class=\"left middle\"\u003eTachometer mode\u003cbr\u003e(cycle measurement)\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\" class=\"left middle\"\u003eAMD-compatible mode\u003cbr\u003e(continuous measurement)\u003c\/td\u003e\n\u003ctd class=\"left middle\"\u003eTachometer mode\u003cbr\u003e(cycle measurement)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" rowspan=\"1\" class=\"heading left middle\"\u003e\u003cstrong\u003eMaximum counting speed\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd class=\"left middle\"\u003e30 Hz\u003cbr\u003e(minimum pulse\u003cbr\u003ewidth: 16.7 ms)\u003c\/td\u003e\n\u003ctd class=\"left middle\"\u003e10 kHz\u003cbr\u003e(minimum pulse\u003cbr\u003ewidth: 0.05 ms)\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\" class=\"center middle\"\u003e---\u003c\/td\u003e\n\u003ctd class=\"left middle\"\u003e30 Hz (minimum pulse\u003cbr\u003ewidth: 16.7 ms) or\u003cbr\u003e5 kHz (minimum pulse\u003cbr\u003ewidth: 0.1 ms)\u003cbr\u003e(selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" rowspan=\"1\" class=\"heading left middle\"\u003e\u003cstrong\u003eMinimum input signal width\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\" class=\"center middle\"\u003e---\u003c\/td\u003e\n\u003ctd class=\"left middle\"\u003e10 ms\u003c\/td\u003e\n\u003ctd class=\"left middle\"\u003e1 ms\u003c\/td\u003e\n\u003ctd class=\"center middle\"\u003e---\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" rowspan=\"1\" class=\"heading left middle\"\u003e\u003cstrong\u003eMeasuring ranges\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd class=\"left middle\"\u003e0.001 Hz to 30.00Hz\u003c\/td\u003e\n\u003ctd class=\"left middle\"\u003e0.001 Hz to 10 kHz\u003c\/td\u003e\n\u003ctd class=\"left middle\"\u003e0.026 to 999999 s\u003c\/td\u003e\n\u003ctd class=\"left middle\"\u003e0.003 to 999999 s\u003c\/td\u003e\n\u003ctd class=\"left middle\"\u003e0.01 to 5k Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" rowspan=\"1\" class=\"heading left middle\"\u003e\u003cstrong\u003eSampling cycle\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\" class=\"left middle\"\u003e200 ms min.\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\" class=\"left middle\"\u003eContinuous measurement\u003cbr\u003e(minimum interval of 10 ms)\u003c\/td\u003e\n\u003ctd class=\"left middle\"\u003e200 ms min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" rowspan=\"1\" class=\"heading left middle\"\u003e\u003cstrong\u003eDisplay refresh cycle\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd colspan=\"5\" rowspan=\"1\" class=\"left middle\"\u003eInput pulse of 5 Hz min.\u003cbr\u003eAveraging not used: 200 ms\u003cbr\u003eAveraging used: 200 multiplied by the averaging setting (ms)\u003cbr\u003eInput pulse of less than 5 Hz\u003cbr\u003eAveraging not used: Two times the maximum input pulse cycle\u003cbr\u003eUsing averaging: Two times the maximum of the input pulse cycle multiplied by the averaging setting.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" rowspan=\"1\" class=\"heading left middle\"\u003e\u003cstrong\u003eMeasuring accuracy\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd colspan=\"5\" rowspan=\"1\" class=\"left middle\"\u003e±0.1% FS ±1 digit max. (at 23 ±5°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" rowspan=\"1\" class=\"heading left middle\"\u003e\u003cstrong\u003eOutput mode\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd colspan=\"4\" rowspan=\"1\" class=\"left middle\"\u003eHI-LO, AREA, HI-HI, LO-LO\u003c\/td\u003e\n\u003ctd class=\"left middle\"\u003eHI-HI, LO-LO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" rowspan=\"1\" class=\"heading left middle\"\u003e\u003cstrong\u003eAuto-zero time\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd colspan=\"5\" rowspan=\"1\" class=\"left middle\"\u003e0.1 to 999.9 s (in Tachometer Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" rowspan=\"1\" class=\"heading left middle\"\u003e\u003cstrong\u003eStartup time\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd colspan=\"5\" rowspan=\"1\" class=\"left middle\"\u003e0.0 to 99.9 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" rowspan=\"1\" class=\"heading left middle\"\u003e\u003cstrong\u003eAveraging\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd colspan=\"5\" rowspan=\"1\" class=\"left middle\"\u003eSimple averaging\/moving averaging selectable, Number of times: OFF, 2, 4, or 8 times\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" rowspan=\"1\" class=\"heading left middle\"\u003e\u003cstrong\u003ePrescaling function\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd colspan=\"5\" rowspan=\"1\" class=\"left middle\"\u003e0.001 to 99.999 (in Tachometer Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" rowspan=\"1\" class=\"heading left middle\"\u003e\u003cstrong\u003eDecimal point adjustment\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd colspan=\"4\" rowspan=\"1\" class=\"left middle\"\u003eRightmost 3 digits\u003c\/td\u003e\n\u003ctd class=\"center middle\"\u003e---\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" rowspan=\"1\" class=\"heading left middle\"\u003e\u003cstrong\u003eSensor waiting time\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd colspan=\"5\" rowspan=\"1\" class=\"left middle\"\u003e290 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"2\" class=\"heading left middle\"\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth class=\"heading left middle\"\u003e\u003cstrong\u003eInput method\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd colspan=\"5\" rowspan=\"1\" class=\"left middle\"\u003eNo-voltage (NPN) input\/voltage (PNP) input (switchable)\u003cbr\u003eNo-voltage Input\u003cbr\u003eImpedance when ON: 1 kΩ max. (Leakage current: 12 mA when 0 Ω)\u003cbr\u003eON residual voltage: 3 V max.\u003cbr\u003eImpedance when OFF: 100 kΩ min.\u003cbr\u003eVoltage Input\u003cbr\u003eHigh (logic) level: 4.5 to 30 VDC\u003cbr\u003eLow (logic) level: 0 to 2 VDC (Input resistance: approx. 4.7 kΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"heading left middle\"\u003e\u003cstrong\u003eHold input\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd colspan=\"4\" rowspan=\"1\" class=\"left middle\"\u003eMinimum input signal width: 20 ms\u003c\/td\u003e\n\u003ctd class=\"center middle\"\u003e---\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" rowspan=\"1\" class=\"heading left middle\"\u003e\u003cstrong\u003eExternal power supply\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd colspan=\"5\" rowspan=\"1\" class=\"left middle\"\u003e12 VDC (±10%), 100 mA\u003cbr\u003e* Refer to Safety Precautions (Common) on Data Sheet for details.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" rowspan=\"1\" class=\"heading left middle\"\u003e\u003cstrong\u003eControl output\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd colspan=\"5\" rowspan=\"1\" class=\"left middle\"\u003eContact output: 3 A at 250 VAC\/30 VDC, resistive load (cosφ=1)\u003cbr\u003eMinimum applied load:10 mA at 5 VDC (failure level: P, reference value)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" rowspan=\"1\" class=\"heading left middle\"\u003e\u003cstrong\u003eDisplay *2\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd colspan=\"5\" rowspan=\"1\" class=\"left middle\"\u003e7-segment, negative transmissive LCD\u003cbr\u003eCharacter height\u003cbr\u003ePresent value: 10 mm (red), comparison value: 6 mm (green)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" rowspan=\"1\" class=\"heading left middle\"\u003e\u003cstrong\u003eDigits\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd colspan=\"5\" rowspan=\"1\" class=\"left middle\"\u003e6 digits (0 to 999999)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" rowspan=\"1\" class=\"heading left middle\"\u003e\u003cstrong\u003eMemory backup\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd colspan=\"5\" rowspan=\"1\" class=\"left middle\"\u003eEEPROM (overwrites: 100,000 times min.) that can store data for 10 years min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" rowspan=\"1\" class=\"heading left middle\"\u003e\u003cstrong\u003eOperating temperature\u003cbr\u003erange\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd colspan=\"5\" rowspan=\"1\" class=\"left middle\"\u003e-10 to 55°C (-10 to 50°C if Counter\/Tachometers are mounted side by side) (with no icing or condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" rowspan=\"1\" class=\"heading left middle\"\u003e\u003cstrong\u003eStorage temperature range\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd colspan=\"5\" rowspan=\"1\" class=\"left middle\"\u003e-25 to 70°C (with no icing or condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" rowspan=\"1\" class=\"heading left middle\"\u003e\u003cstrong\u003eOperating humidity range\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd colspan=\"5\" rowspan=\"1\" class=\"left middle\"\u003e25% to 85%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" rowspan=\"1\" class=\"heading left middle\"\u003e\u003cstrong\u003eCase color\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd colspan=\"5\" rowspan=\"1\" class=\"left middle\"\u003eBlack (N1.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"component-blockA01\"\u003e\n\u003cdiv class=\"text\"\u003e\n\u003cp\u003e*1. Do not use the output from an inverter as the power supply. The ripple must be 20% maximum for CC power.\u003cbr\u003e*2. The display is lit only when the power is ON. Nothing is displayed when power is OFF.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"heading-A02\"\u003eCharacteristics\u003c\/h4\u003e\n\u003cdiv class=\"component-blockA01\"\u003e\n\u003cdiv class=\"text\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"table-blockA01\"\u003e\n\u003ctable border=\"0\" cellspacing=\"0\" class=\"tableA01\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" rowspan=\"1\" class=\"heading left middle\"\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd class=\"left middle\"\u003e100 MΩ min. (at 500 VDC) between current-carrying terminal and exposed non-current-carrying metal parts, and between non-continuous contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" rowspan=\"1\" class=\"heading left middle\"\u003e\u003cstrong\u003eDielectric strength\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd class=\"left middle\"\u003e2,000 VAC, 50\/60 Hz for 1 min between current-carrying metal parts and non-current-carrying metal parts\u003cbr\u003e2,000 VAC (for 100 to 240 VAC), 50\/60 Hz for 1 min between power supply and input circuit (1,000 VAC for 24 VAC\/12 to 24 VDC)\u003cbr\u003e2,000 VAC 50\/60 Hz for 1 min between control output, power supply, and input circuit\u003cbr\u003e1,000 VAC, 50\/60 Hz for 1 min between non-continuous contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" rowspan=\"1\" class=\"heading left middle\"\u003e\u003cstrong\u003eImpulse withstand voltage\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd class=\"left middle\"\u003e3.0 kV (between power terminals) for 100 to 240 VAC, 1.0 kV for 24 VAC\/12 to 24 VDC\u003cbr\u003e4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) for 100 to 240 VAC, 1.5 kV for 24 VAC\/12 to 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" rowspan=\"1\" class=\"heading left middle\"\u003e\u003cstrong\u003eNoise immunity\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd class=\"left middle\"\u003e±1.5 kV (between power terminals)\u003cbr\u003e±600 V (between input terminals)\u003cbr\u003eSquare-wave noise by noise simulator (pulse width: 100 ns\/1 μs, 1-ns rise)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" rowspan=\"1\" class=\"heading left middle\"\u003e\u003cstrong\u003eStatic immunity\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd class=\"left middle\"\u003eDestruction: 15 kV, Malfunction: 8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"2\" class=\"heading left middle\"\u003e\u003cstrong\u003eVibration\u003cbr\u003eresistance\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd class=\"heading left middle\"\u003e\u003cstrong\u003eDestruction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"left middle\"\u003e10 to 55 Hz with 0.75-mm single amplitude, each in three directions for 2 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"heading left middle\"\u003e\u003cstrong\u003eMalfunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd class=\"left middle\"\u003e10 to 55 Hz with 0.35-mm single amplitude, each in three directions for 10 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"2\" class=\"heading left middle\"\u003e\u003cstrong\u003eShock\u003cbr\u003ere-sistance\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd class=\"heading left middle\"\u003e\u003cstrong\u003eDestruction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"left middle\"\u003e300m\/s\u003csup\u003e2\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eeach in three directions, three cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"heading left middle\"\u003e\u003cstrong\u003eMalfunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd class=\"left middle\"\u003e100m\/s\u003csup\u003e2\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eeach in three directions, three cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" rowspan=\"1\" class=\"heading left middle\"\u003e\u003cstrong\u003eLife expectancy\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd class=\"left middle\"\u003eMechanical: 10,000,000 operations min.\u003cbr\u003eElectrical: 100,000 operations min. (3 A at 250 VAC, resistive load, ambient temperature condition: 23°C) *\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" rowspan=\"1\" class=\"heading left middle\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd class=\"left middle\"\u003eApprox. 110 g (Tachometer only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"component-blockA01\"\u003e\n\u003cdiv class=\"text\"\u003e\n\u003cp\u003e* See Life-test Curve (Reference Values).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"heading-B02\"\u003eLife-test Curve (Reference Values)\u003c\/h4\u003e\n\u003ch4 class=\"heading-B02\"\u003eResistive Load\u003c\/h4\u003e\n\u003cdiv class=\"component-blockA01\"\u003e\n\u003cdiv class=\"image\"\u003e\u003cimg src=\"https:\/\/www.omron-ap.com\/Images\/1450_sp_325-104724.gif\" alt=\"H7CX-R Specifications 6\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"heading-B02\"\u003eInductive Load\u003c\/h4\u003e\n\u003cdiv class=\"component-blockA01\"\u003e\n\u003cdiv class=\"image\"\u003e\u003cimg src=\"https:\/\/www.omron-ap.com\/Images\/1450_sp_425-104726.gif\" alt=\"H7CX-R Specifications 7\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"text\"\u003e\n\u003cp\u003eA current of 0.15 A max. can be switched at 125 VDC (cosφ=1) (Life expectancy: 100,000 operations)\u003cbr\u003eA current of 0.1 A max. can be switched if L\/R=7 ms.\u003cbr\u003e(Life expectancy: 100,000 operations)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"heading-A02\"\u003eApplicable Standards\u003c\/h4\u003e\n\u003cdiv class=\"component-blockA01\"\u003e\n\u003cdiv class=\"text\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"table-blockA01\"\u003e\n\u003ctable border=\"0\" cellspacing=\"0\" class=\"tableA01\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"first-child\"\u003e\n\u003cth class=\"heading left middle\"\u003e\u003cstrong\u003eApproved\u003cbr\u003esafety\u003cbr\u003estandards\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd class=\"left middle\"\u003ecULus (or cURus): UL508\/CSA C22.2 No. 14 *1\u003cbr\u003eConforms to EN 61010-1 (IEC 61010-1): Pollution degree 2\/overvoltage category II, B300 PILOT DUTY,\u003cbr\u003e1\/4 HP 120 VAC, 1\/3 HP, 240 VAC, 3-A resistive load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"heading left middle\"\u003e\u003cstrong\u003eEMC\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd class=\"left middle\"\u003e(EMI) EN61326-1 *2\u003cbr\u003eEmission Enclosure: EN55011 Group 1 classA\u003cbr\u003eEmission AC mains: EN55011 Group 1 classA\u003cbr\u003e(EMS) EN61326-1 *2\u003cbr\u003eImmunity ESD: EN61000-4-2: 4 kV contact discharge (level 2); 8 kV air discharge (level 3)\u003cbr\u003eImmunity RF-interference: EN61000-4-3: 10 V\/m (Amplitude-modulated, 80 MHz to 1 GHz) (level 3);\u003cbr\u003e10 V\/m (Pulse-modulated, 900 MHz ±5 MHz) (level 3)\u003cbr\u003eImmunity Conducted Disturbance: EN61000-4-6: 10 V (0.15 to 80 MHz) (level 3)\u003cbr\u003eImmunity Burst: EN61000-4-4: 2 kV power-line (level 3); 1 kV I\/O signal-line (level 4)\u003cbr\u003eImmunity Surge: EN61000-4-5: 1 kV line to lines (power and output lines) (level 2); 2 kV line to ground\u003cbr\u003e(power and output lines) (level 3)\u003cbr\u003eImmunity Voltage Dip\/Interruption: EN61000-4-11: 0.5 cycle, 100% (rated voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"component-blockA01\"\u003e\n\u003cdiv class=\"text\"\u003e\n\u003cp\u003e*1. The following safety standards apply to the H7CX-R11[].\u003cbr\u003e     cUL (Listing): Applicable when an OMRON P2CF(-E) Socket is used.\u003cbr\u003e     cUR (Recognition): Applicable when any other socket is used.\u003cbr\u003e*2. Industrial electromagnetic environment (EN\/IEC 61326-1 Table 2)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"heading-A02\"\u003eI\/O Functions\u003c\/h4\u003e\n\u003cdiv class=\"component-blockA01\"\u003e\n\u003cdiv class=\"text\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"table-blockA01\"\u003e\n\u003ctable border=\"0\" cellspacing=\"0\" class=\"tableA01\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"2\" class=\"heading left middle\"\u003e\u003cstrong\u003eInputs\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd class=\"heading left middle\"\u003e\u003cstrong\u003eCount, count 1, count 2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"left middle\"\u003eReads counting signals.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"heading left middle\"\u003e\u003cstrong\u003eHold\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd class=\"left middle\"\u003eHolds the measurement value and outputs.\u003cbr\u003eThe hold indicator is lit during hold. *\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"heading left middle\"\u003e\u003cstrong\u003eOutputs\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd class=\"heading left middle\"\u003e\u003cstrong\u003eOUT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"left middle\"\u003eOutputs signals according to the specified output mode when a comparison\u003cbr\u003evalue is reached.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"component-blockA01\"\u003e\n\u003cdiv class=\"text\"\u003e\n\u003cp\u003e* Refer to Data Sheet for details on the hold function.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"component-blockA01\"\u003e\n\u003cdiv class=\"text\"\u003e\n\u003cp\u003eThe following table shows the delay from when the reset signal is input until the output is turned OFF. (Reference values)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"component-blockA01 set-width\"\u003e\n\u003cdiv class=\"text\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"table-blockA01\"\u003e\n\u003ctable border=\"0\" cellspacing=\"0\" class=\"tableA01\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"heading center middle\"\u003e\u003cstrong\u003eMinimum reset signal width\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd class=\"heading center middle\"\u003e\u003cstrong\u003eOutput delay time\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"center middle\"\u003e1 ms\u003c\/td\u003e\n\u003ctd class=\"center middle\"\u003e0.8 to 1.2 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"center middle\"\u003e20 ms\u003c\/td\u003e\n\u003ctd class=\"center middle\"\u003e15 to 25 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":50971086618909,"sku":"H7CX-R11D1-N","price":36853.0,"currency_code":"KES","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/5596\/8285\/files\/l_1450-25-118932-198x198.jpg?v=1779260133","url":"https:\/\/www.thameselectricals.com\/sw\/products\/techometer-48-48mm-socket-type-h7cx-r11d1-n-omron","provider":"Thames Electrical","version":"1.0","type":"link"}